Operation CHARM: Car repair manuals for everyone.

Air Recirculation Malfunction




Air Recirculation Malfunction

Diagnostic Instructions

* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.

* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.

* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.

Diagnostic Fault Information






Circuit/System Description

The desired position of the recirculation flap can be set with the recirculation switch at the HVAC controls. The selected value is passed to the HVAC control module via the LIN-Bus. The HVAC control module supplies a 12 V reference voltage to the stepper motor and energizes the 4 stepper motor coils with a pulsed ground signal. The stepper motor puts the recirculation flap into the selected position.

Diagnostic Aids

Check the following mechanical fault sources:

* Air distribution box

* Air distribution hoses/air distribution ducts

Reference Information

Schematic Reference

HVAC Schematics HVAC - Manual

Connector End View Reference

Component Connector End Views Sunshade - Left (DH6)

Description and Operation

Manual HVAC Description and Operation HVAC - Manual

Electrical Information Reference

* Circuit Testing Circuit Testing

* Connector Repairs Connector Repairs

* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections

* Wiring Repairs Wiring Repairs

Scan Tool Reference

Control Module References Control Module References for scan tool information

Circuit/System Testing

1. Ignition ON, activate and deactivate the defrost switch. Verify the scan tool Enhanced Defrost Switch parameter changes between Active and Inactive.

If the parameter does not change

Replace the A26 HVAC Controls.

If the parameter changes

2. Activate and deactivate the recirculation switch. Verify the scan tool Air Recirculation Mode Switch parameter changes between Active and Inactive.

If the parameter does not change

Replace the A26 HVAC Controls.

If the parameter changes

3. Replace the M46 Air Recirculation Door Actuator and verify the M46 Air Recirculation Door Actuator can be put into all positions.

If the M46 Air Recirculation Door Actuator cannot be put into all positions

Replace the K33 HVAC Control Module.

If the M46 Air Recirculation Door Actuator can be put into all positions

4. All OK.

Repair Instructions

Perform the Diagnostic Repair Verification Verification Tests after completing the diagnostic procedure.

* Heater and Air Conditioning Control Replacement Heater and Air Conditioning Control Replacement

* Air Inlet Valve Actuator Replacement Air Inlet Valve Actuator Replacement

* Control Module References Control Module References for HVAC control module replacement, setup, and programming