C0267
DTC C0267
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.
DTC Descriptor
DTC C0267
-
Low Brake Fluid Indicated
Diagnostic Fault Information
Circuit/System Description
The brake fluid level switch monitors the level of brake fluid in the brake fluid reservoir.
Conditions for Running the DTC
Ignition ON
Conditions for Setting the DTC
* A short to ground detected on the brake fluid level signal circuit for 5 s.
* Low brake fluid level is detected for 5 s.
Conditions for Clearing the DTC
The condition for setting the DTC is no longer present.
Reference Information
Schematic Reference
Hydraulic Brake Schematics [1][2]Electrical Diagrams
Connector End View Reference
Component Connector End Views Fuel Pump and Level Sensor Assembly
Description and Operation
Brake Warning System Description and Operation Brake Warning System
Electrical Information Reference
* Circuit Testing Circuit Testing
* Connector Repairs Connector Repairs
* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections
* Wiring Repairs Wiring Repairs
Scan Tool Reference
Control Module References Control Module References for scan tool information
Circuit/System Verification
1. Inspect for proper brake fluid level. The fluid level should be above minimum level.
• If low, refer to Brake Fluid Loss Brake Fluid Loss.
2. Ignition ON, observe the scan tool Brake Fluid Level Sensor parameter. The reading should be OK.
Circuit/System Testing
1. Ignition OFF, disconnect the harness connector at the B20 Brake Fluid Level Switch.
2. Test for less than 5 ohms between the ground circuit terminal 2 and ground.
• If greater than the specified range, test the ground circuit for an open/high resistance.
3. Ignition ON, verify the scan tool Brake Fluid Level Sensor parameter is OK.
• If not the specified value, test the signal circuit for a short to ground. If the circuit tests normal, replace the K17 Electronic Brake Control Module.
4. Install a 3 A fused jumper wire between the signal circuit terminal 1 and ground.
5. Verify the scan tool Brake Fluid Level Sensor parameter is Low.
• If not the specified value, test the signal circuit for a short to voltage or an open/high resistance. If the circuit tests normal, replace the K17 Electronic Brake Control Module.
6. If all circuits test normal, test or replace the B20 Brake Fluid Level Switch.
Component Testing
Static Test
1. Ignition OFF, disconnect the harness connector at the B20 Brake Fluid Level Switch.
2. Test for greater than 5 ohms between the ground circuit terminal 2 and the signal circuit terminal 1.
• If less than the specified value, replace the B20 Brake Fluid Level Switch. Infinite resistance between signal terminal 1 and ground.
Repair Instructions
Perform the Diagnostic Repair Verification Verification Tests after completing the repair.
* Master Cylinder Reservoir Replacement (Left Hand Drive) Service and Repair
* Control Module References Control Module References for control module replacement, programming and setup