Dome Lamps Malfunction
Dome Lamps Malfunction
Diagnostic Instructions
* Perform the Diagnostic System Check - Vehicle Diagnostic System Check - Vehicle prior to using this diagnostic procedure.
* Review Strategy Based Diagnosis Strategy Based Diagnosis for an overview of the diagnostic approach.
* Diagnostic Procedure Instructions Diagnostic Procedure Instructions provides an overview of each diagnostic category.
Diagnostic Fault Information
Circuit/System Description
When any door is opened, the door ajar switch contacts close and the body control module (BCM) receives a door-open input. The BCM illuminates the dome lamp when any door is opened or a door lock/unlock request is activated with the key fob. After all doors have been closed, the dome lamp will remain illuminated approximately 3 seconds after the last door closes. In the event that the dome lamp were to remain illuminated for more than 10 minutes with the ignition switch in the OFF position and no doors opened, the BCM will deactivate the dome lamp control circuit to prevent total battery discharge.
Reference Information
Schematic Reference
Interior Lights Schematics Interior Lights Schematics
Connector End View Reference
Component Connector End Views Fuel Pump and Level Sensor Assembly
Description and Operation
Interior Lighting Systems Description and Operation Interior Lighting Systems
Electrical Information Reference
* Circuit Testing Circuit Testing
* Connector Repairs Connector Repairs
* Testing for Intermittent Conditions and Poor Connections Testing for Intermittent Conditions and Poor Connections
* Wiring Repairs Wiring Repairs
Scan Tool Reference
Control Module References Control Module References for scan tool information
Circuit/System Verification
1. Ignition ON.
2. Verify the scan tool Door Ajar Sw. parameter changes between Active and Inactive while opening and closing each vehicle door.
• If the parameter does not change
Refer to Door Ajar Indicator Malfunction Door Ajar Indicator Malfunction.
• If the parameter changes
3. Verify the dome lamps turn ON and OFF while commanding the Courtesy Lamps ON and OFF with a scan tool.
• If the dome lamps do not turn ON and OFF
Refer to Circuit/System Testing.
• If the dome lamps turn ON and OFF
4. All OK.
Circuit/System Testing
1. Ignition OFF, all doors closed, all accessories OFF, disconnect the harness connector at the E37F dome/reading lamps - front and E37 B dome/reading lamps - 2nd row. It may take up to 2 minutes for all vehicle systems to power down.
2. Test for less than 10 ohms between the appropriate ground circuit terminal listed below and ground.
* E37F dome reading lamps - front - terminal 2 with C90/C91
* E37F dome reading lamps - front - terminal 6 with C95
* E37B dome reading lamps - 2nd row - terminal 2 with C90/C95
• If 10 ohms or greater
1. Ignition OFF.
2. Test for less than 2 ohms in the ground circuit end to end.
• If 2 ohms or greater, repair the open/high resistance in the circuit.
• If less than 2 ohms, repair the open/high resistance in the ground connection.
• If less than 10 ohms
3. Connect a test lamp between the appropriate control circuit terminal listed below and ground.
* E37F dome reading lamps - front - terminal 3 with C90/C91
* E37F dome reading lamps - front - terminal 2 with C95
* E37B dome reading lamps - 2nd row - terminal 3 with C90/C95
4. Verify the test lamp turns ON and OFF when commanding the Courtesy Lamps ON and OFF with a scan tool.
• If the test lamp is always OFF
1. Ignition OFF, disconnect the X7 harness connector at the K9 body control module.
2. Test for infinite resistance between the control circuit and ground.
• If less than infinite resistance, repair the short to ground on the circuit.
• If infinite resistance
3. Test for less than 2 ohms in the control circuit end to end.
• If 2 ohms or greater, repair the open/high resistance in the circuit.
• If less than 2 ohms, replace the K9 body control module.
• If the test lamp is always ON
1. Ignition OFF, disconnect the X7 harness connector at the K9 body control module, ignition ON.
2. Test for less than 1 V between the control circuit terminal and ground.
• If 1 V or greater, repair the short to voltage on the circuit.
• If less than 1 V, replace the K9 body control module.
• If the test lamp turns ON and OFF
5. Test or replace the inoperative E37 dome/reading lamp.
Repair Instructions
Perform the Diagnostic Repair Verification Verification Tests after completing the repair.
* Dome Lamp Bulb Replacement Service and Repair
* Control Module References Control Module References for BCM replacement, programming, and setup