Scan Tool Does Not Communicate With Class 2 Device
Diagnostic Chart (Part 1 Of 4):
Diagnostic Chart (Part 2 Of 4):
Diagnostic Chart (Part 3 Of 4):
Diagnostic Chart (Part 4 Of 4):
CIRCUIT DESCRIPTION
Modules connected to the class 2 serial data circuit monitor for serial data communications during normal vehicle operation. Operating information and commands are exchanged among the modules. Connecting a scan tool to the DLC allows communication with the modules for diagnostic purposes. Diagnostic trouble codes (DTCs) may be set due to this symptom and during this diagnostic procedure. Complete the diagnostic procedure in order to ensure all the DTCs are diagnosed and cleared from memory.
DIAGNOSTIC AIDS
^ When the class 2 serial data circuit is shorted to ground, U1300 will be set. Refer to DTC U1300 Class 2 Data Link Low.
^ When the class 2 serial data circuit is shorted to B+, U1301 will be set. Refer to DTC U1301 Class 2 Data Link High.
TEST DESCRIPTION
The number(s) below refer to the step number(s) on the diagnostic table.
2. A partial malfunction in the class 2 serial data circuit uses a different procedure from a total malfunction of the class 2 serial data circuit. The following modules communicate on the class 2 serial data circuit:
^ Powertrain Control Module/Vehicle Control Module (PCM/VCM)
^ Automatic Transfer Case (ATC)
^ Inflatable Restraint Sensing and Diagnostic Module (SDM)
^ Instrument Cluster (IPC)
^ Body Control Module (BCM)
^ Electronic Brake Control Module (EBCM)
^ Suspension Control Module (SCM)
^ HVAC Control Module
3. The following DTCs may be retrieved with a history status:
^ U1300
^ U1301
These DTCs are not the cause of the present condition.
4. A State of Health DTC with a history status may be present along with a U1000 or U1255 having a current status. This indicates that the malfunction occurred when the ignition was ON.
5. Data link connector terminals 2 and 5 provide the connection to the class 2 serial data circuit and the signal ground circuit respectively.
7. A poor connection at terminal A would cause this condition but will not set a DTC.
8. An open in the class 2 serial data circuit between the DLC and splice pack SP 205 will prevent the scan tool from communicating with any module. This condition will not set a DTC.
9. The class 2 serial data circuit is shorted to voltage or ground. The condition may be due to the wiring or due to a malfunction in one of the modules. When testing the wiring for a short, make sure there is not a module connected to the wire being tested. This test isolates the BCM class 2 serial data circuit.
11. This test isolates the PCM/VCM class 2 serial data circuit.
13. This test isolates the ATC class 2 serial data circuit.
15. This test isolates the EBCM class 2 serial data circuit.
17. This test isolates the SDM class 2 serial data circuit.
19. This test isolates the IPC class 2 serial data circuit.
32. If there are no current DTCs that begin with a U, the communication malfunction has been repaired.