Operation CHARM: Car repair manuals for everyone.

HO2S 2

The scan tool range is 0-1275 mV. The rear HO2S 2 represents the exhaust oxygen output voltage beyond the catalytic converter. This voltage will remain inactive or appear lazy within a range 100 mV (lean exhaust) and 900 mV (rich exhaust) when the system is operating in closed loop.