Generator Bracket Replacement
REMOVAL PROCEDURE1. Remove the generator.
2. Remove the drive belt tensioner.
3. Remove the drive belt idler pulley.
4. Remove the generator bracket bolts (2) and nut.
INSTALLATION PROCEDURE
NOTE: Refer to Fastener Notice in Service Precautions.
1. Install the generator bracket bolts (2) and nut.
Tighten
- Tighten the generator bracket bolts to 50 N.m (37 lb ft).
- Tighten the generator bracket nut to 41 N.m (30 lb ft).
2. Install the drive belt idler pulley.
3. Install the drive belt tensioner.