Operation CHARM: Car repair manuals for everyone.

Blower Motor Control Processor Replacement - HVAC System - Automatic

REMOVAL PROCEDURE




1. Disconnect the electrical connector at the blower motor.




2. Disconnect the electrical connector (4) from the blower motor control processor (2).
3. Remove the blower motor control processor retaining screws (3) from the HVAC module (1).
4. Remove the blower motor control processor (2) from the HVAC module (1).

INSTALLATION PROCEDURE




1. Install the blower motor control processor (2) to the HVAC module (1).

NOTE: Refer to Fastener Notice in Service Precautions.

2. Install the blower motor control processor retaining screws.

Tighten
Tighten the screws to 1.6 N.m (14 lb in).

3. Connect the electrical connector (4) to the blower motor control processor (2).




4. Connect the electrical connector at the blower motor.