Fuel Level Sensor Replacement (Escalade Ext)
REMOVAL PROCEDURE1. Remove the sending unit.
2. Place the sending unit on a clean work surface.
3. Disconnect the fuel level sensor electrical connector (1) from the module connector.
4. Remove the fuel level sensor retaining clip.
5. Release the fuel sender reservoir retaining tabs on both sides of the reservoir (1).
IMPORTANT: Extreme care must be used when disengaging the locking tabs on the reservoir, failure to do so may result in the sender being unusable.
6. Remove the fuel level sensor wires from around the reservoir retaining tabs.
7. Separate the module from the reservoir.
8. Squeeze the retaining tabs together in order to slide the fuel lever sensor off of the reservoir.
INSTALLATION PROCEDURE
1. Slide the fuel lever sensor onto the reservoir until the retaining tabs snap into place.
2. Slide the module into the reservoir.
3. Route the fuel level sensor wires around the reservoir retaining tabs.
4. Snap the sending unit reservoir retaining tabs (1) into both sides of the reservoir.
5. Install the fuel level sensor retaining clip.
6. Connect the fuel level sensor electrical connector (1) to the module connector.
7. Install the sending unit.