Fuel Gage Inaccurate or Inoperative - Dual Tanks
FUEL GAGE INACCURATE OR INOPERATIVE (DUAL TANK)DIAGNOSTIC AIDS
- Verify that the fuel level is in the same range as the customer concern.
- Refer to Fuel Level Specifications in order to verify the correct readings for the fuel level sensor. The Fuel Tank Level Remaining % parameter is available on the scan tool in the PCM Enhanced EVAP data list.
TEST DESCRIPTION
Steps 1-2:
Step 3:
Steps 4-7:
Steps 8-11:
Steps 12-13:
The numbers below refer to the step numbers on the diagnostic table.
3. This step tests for a high resistance in the signal circuit and the low reference circuit of the fuel level sensor.
13. DTCs will set in the PCM when you perform this diagnostic table.