Barometric Pressure Sensor: Service and Repair
Barometric Pressure SensorREMOVAL PROCEDURE
1. Disconnect the barometric pressure (BARO) sensor electrical connector (1).
2. Bend the tabs (2), located on the bracket, away from the sensor, enough so that the sensor can be removed.
3. Pull the BARO sensor (3) downward in order to remove it from the bracket.
INSTALLATION PROCEDURE
1. Install the BARO sensor (3) to the bracket.
2. Bend the tabs (2) inward to hold the sensor.
3. Connect the BARO sensor electrical connector (1).