Tyco/AMP Connectors (102-Way Inline)
Tyco/AMP Connectors (102-Way Inline)
Tools Required
J-38125 Terminal Repair Kit
Removal Procedure
View of a typical connector in the assembled position.
1. Pull the locking lever to the 90 degree position from the connector body.
2. With the locking lever in the 90 degree position and the male connector body separated, it can be slid outward for removal.
3. Slide the male connector body out away from the guide plates.
4. Using terminal release tool 7J04898 or equivalent, remove the TPA from the connector body.
Note: During assembly the TPA will not fully seat if any terminal is not fully seated.
5. Using terminal release tool J-38125-566, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body.
6. Using terminal release tool J-38125-560, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body.
7. Using terminal release tool J-38125-221, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body.
8. The female connector body may have an additional connector hooked to the edge of the body. Use terminal release tool 7J04898 or equivalent to release the locking tab and slide the connector off the female body.
9. Move the locking lever 180 degrees from the connected position.
10. With the locking lever in the 180 degree position the guide plates can be removed from the connector body.
11. Using terminal release tool 7J04898 or equivalent, remove the TPA from the connector body.
Note: During assembly the TPA will not fully seat if any terminal is not fully seated.
12. Using terminal release tool J-38125-216, lift the terminal plate past the terminals and out of the connector body cavity.
13. Terminal plate will bind slightly on each corner.
14. Using terminal release tool J-38125-221, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body.
15. Using terminal release tool J-38125-212, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body.
16. Using terminal release tool J-38125-560, press the prongs into the holes on each side of the terminal to be removed to release the lock tabs and pull the terminal out of the connector body.
17. With the locking lever in the 180 degree position, align the guide plates to mesh with the gears on the locking lever.
Terminal Repair Procedure
Use the appropriate terminal and crimper in the J-38125 in order to replace the terminal.