Battery Power to Module Disconnected
Name of Code:Battery Power to Module Disconnected
When Monitored:
Anytime battery voltage is above 10 volts and BCM is awake.
Set Condition:
Battery power to the BCM is disconnected while the ignition is on.
Theory of Operation:
The body control module checks battery input and determines if the battery is connected.
Possible Causes:
- In shipping mode - IOD fuse missing
- Open wire