Driver Squib Circuit Open (Active)
Test 1:
Tests 2 - 4:
Test 5:
SYMPTOM
DRIVER SQUIB CIRCUIT OPEN (ACTIVE)
WHEN MONITORED:
Continuously with ignition ON.
SET CONDITION:
The ACM has detected an open or high resistance in the Driver Squib Circuits.
POSSIBLE CAUSES
- Driver airbag line 1 open
- Driver airbag line 2 open
- Clockspring open
- Driver airbag module open
- ACM defective, driver airbag circuit open