Driver Squib Terminal Shorted to Ground (Active)
Test 1:
Tests 2 - 4:
SYMPTOM
DRIVER SQUIB TERMINAL SHORTED TO GROUND (ACTIVE)
WHEN MONITORED:
Continuously with ignition ON.
SET CONDITION:
With voltage and current on, the driver airbag line 1 or line 2 circuit(s) is other than expected.
POSSIBLE CAUSES
- Driver airbag line 1 or line 2 shorted to ground
- Clockspring shorted to ground
- Driver airbag module internal shorted to ground
- ACM DEFECTIVE, Driver airbag terminal shorted to ground