Operation CHARM: Car repair manuals for everyone.

Passenger Squib Terminal Shorted to Ground (Active)

Test 1:




Tests 2 - 3:




SYMPTOM
PASSENGER SQUIB TERMINAL SHORTED TO GROUND (ACTIVE)

WHEN MONITORED:
Continuously with ignition ON.

SET CONDITION:
With voltage and current on, the passenger airbag line 1 or line 2 circuit(s) is other than expected.

POSSIBLE CAUSES
- Passenger airbag line 1 or line 2 shorted to ground
- Passenger airbag module shorted to ground
- ACM Defective, passenger airbag shorted to ground