P0134
Tests 1 - 2:
Tests 3 - 7:
SYMPTOM
P0134 - 1/1 O2 SENSOR STAYS AT CENTER
WHEN MONITORED
With the engine running for more than 2 minutes and engine temperature greater than 76 °C (170 °F).
SET CONDITION
The Upstream Oxygen Sensor Signal voltage is between 0.35 volt and 0.55 volt for 1.5 minutes.
POSSIBLE CAUSES
- O2 sensor 1/1 ground circuit open
- O2 sensor 1/1 signal circuit open
- 1/1 O2 sensor wiring harness inter defect
- 1/1 O2 sensor wiring harness observable defect
- O2 sensor 1/1 defective
- PCM defective