P0141
Tests 1 - 3:
Tests 4 - 7:
SYMPTOM
P0141 - 1/2 O2 SENSOR HEATER FAILURE
WHEN MONITORED
With the ignition key OFF, after the engine cools down.
SET CONDITION
No sensor output signal is received when the PCM powers up the sensor heater.
POSSIBLE CAUSES
- 1/2 O2 sensor connector damaged
- 1/2 O2 sensor ground circuit open
- ASD relay output circuit open
- 1/2 O2 sensor failure
- 1/2 O2 sensor heater element failure
- 1/2 O2 sensor heater failure does not reoccur