Operation CHARM: Car repair manuals for everyone.

Combination/Proportioning Valve

There are two different type proportioning valves used on this vehicle depending brake system application. Vehicles equipped with Antilock Brakes (ABS) use a fixed proportioning valve. Vehicles not equipped with ABS use a height sensing proportioning valve.
Information on the height sensing proportioning valve is covered in Hydraulic System. Proportioning Valve, Information on the fixed proportioning valve is covered in Antilock Brake System.

CAUTION: The use of after-market load leveling or load capacity increasing devices on this vehicle are prohibited. Using air shock absorbers or helper springs on this vehicle will cause the height sensing proportioning valve to inappropriately reduce the hydraulic pressure to the rear brakes. This inappropriate reduction in hydraulic pressure potentially could result in increased stopping distance of the vehicle.

HEIGHT SENSING PROPORTIONING VALVE
DESCRIPTION







Vehicles not equipped with ABS brakes use a height sensing proportioning valve. The height sensing proportioning valve is mounted on the left frame rail in front of the rear axle. The height sensing proportioning valve uses an actuator to attach the proportioning valve to the left rear spring for sensing changes in vehicle height.

OPERATION
The height sensing proportioning valve operates similarly to a standard proportioning valve in the following way. As hydraulic pressure is applied to the valve, full input hydraulic pressure is supplied to the rear brakes up to a certain pressure point, called the split point. Beyond the split point, the proportioning valve reduces the amount of hydraulic pressure to the rear brakes according to a given ratio. Thus, on light brake applications, approximately equal hydraulic pressure will be transmitted to both the front and rear brakes. Upon heavier brake applications, the hydraulic pressure transmitted to the rear brakes will be lower than the front brakes. This will prevent premature rear wheel lock-up and skid.
Here is how the height sensing proportioning valve differs from a standard proportioning valve. As the height of the rear suspension changes, the height sensing portion of the proportioning valve changes the split point of the proportioning valve. When the height of the rear suspension is low, the proportioning valve interprets this as extra load and the split point of the proportioning valve is raised to a higher pressure to allow for more rear braking. When the height of the rear suspension is high, the proportioning valve interprets this as a light load and the split point of the proportioning valve is lowered to a lower pressure and rear braking is reduced.
The height sensing proportioning valve regulates the pressure by sensing the load condition of the vehicle through the movement of the proportioning valve actuator. The actuator is mounted between the height sensing proportioning valve and the actuator bracket on the left rear leaf spring. As the position of the left rear leaf spring changes, depending on the load the vehicle is carrying, the movement is transferred through the actuator bracket and actuator, to the proportioning valve. The proportioning valve adjusts the hydraulic pressure accordingly.
The height sensing proportioning valve allows the brake system to maintain the optimal front to rear brake balance regardless of the vehicle load condition. Under a light load condition, hydraulic pressure to the rear brakes is minimized. As the rear load condition increases, so does the hydraulic pressure to the rear brakes.