Quarter Window Motor: Service and Repair
REMOVAL1. Disconnect and isolate the battery negative cable.
2. Remove D-pillar trim panel.
3. Disconnect wire connector from power vent motor.
4. Remove nut holding crank to vent glass.
Vent Window Motor:
5. Remove bolts holding power vent motor to D-pillar.
6. Remove power vent motor.
7. Pull the crank system from the motor.
INSTALLATION
Before installing crank, cycle replacement motor to the open position. Install crank hinge in extended position to the motor and for installation, reverse the above procedures.