Operation CHARM: Car repair manuals for everyone.

Recirculation Calibration Fault

Tests 2 - 3:




Tests 4 - 6:




Test 7:




SYMPTOM
RECIRCULATION CALIBRATION FAULT - MANUAL A/C

TEST NOTE
This symptom is diagnosed using the test BLEND CALIBRATION FAULT - MANUAL A/C.

WHEN MONITORED
When the HVAC Door Recalibration is executed. With the ignition ON (door actuator(s)/circuit(s) shorted low only).

SET CONDITION
If the Recirculation Door drive span found is outside the tolerance. If the Recirculation Door Actuator/circuit is open. If the Blend Door(s) (Driver [Zone], Pass, Rear), Mode Door(s) (Front, Rear), Recirculation Door Actuator(s)/circuit(s) are shorted low. (This will also set Blend Calibration/Overcurrent (Front, Rear), Mode Calibration/ Overcurrent (Front, Rear), Recirculation Calibration/Overcurrent, Zone Calibration/ Overcurrent DTCs.)

POSSIBLE CAUSES
- Additional code(s) present
- Door actuator
- Blend actuator/linkage/door
- Recirculation actuator/linkage/door
- Mode actuator/lineage/door
- Door actuator driver circuit open
- Common door driver circuit open
- A/C - heater control module