Body Control System
B210D-BATTERY VOLTAGE LOWWHEN MONITORED
With the ignition on.
SET CONDITION
Battery voltage less than 9 volts for more than 15 seconds.
POSSIBLE CAUSES
- Resistance in the (A1) battery positive circuit
- Resistance in the generator case ground
- Generator operation
- Generator field control circuit open
- Generator field control circuit shorted to ground
- Ground circuit open
- PCM/ECM
Diagnostic Test
1. CHECK FOR ANY POWERTRAIN/ENGINE CONTROL MODULES DTCS
NOTE:
- Make sure the Battery is in good condition. Using the Midtronics Battery Tester, test the Battery before continuing.
- Inspect the vehicle for after market accessories that may exceed the Generator System output.
- Make sure the generator drive belt is in good operating condition.
- Inspect the fuses in the TIPM. If an open fuse is found, use the wire diagram/schematic as a guide, inspect the wiring and connectors for damage.
Turn the ignition on.
With the scan tool, read active PCM/ECM DTC's.
Q: Does the scan tool display any active DTC's?
YES: Refer to Computers and Control Systems/Testing and Inspection for the diagnostic test procedure.
NO: Check the above conditions that can cause a low voltage condition. Repair as necessary.