Instrument Cluster
B210E-BATTERY VOLTAGE HIGHWHEN MONITORED
With the ignition on.
SET CONDITION
The Instrument Cluster detects a battery voltage of 16.0 volts for 5 seconds.
POSSIBLE CAUSES
- Vehicle charging system
- Instrument cluster
Diagnostic Test
1. CHECK FOR ACTIVE DTC: B210E-BATTERY VOLTAGE HIGH
Turn the ignition on.
Apply the vehicle park brake.
Shift the transmission into reverse.
With the scan tool, record and erase Instrument Cluster DTCs.
Wait 30 seconds.
With the scan tool, read Instrument Cluster DTCs.
Q: Does the scan tool display: B210E-BATTERY VOLTAGE HIGH?
YES: Go To 2
NO: The condition that caused this code to set is not present at this time. Check for an intermittent condition by inspecting the related wiring harness for chaffed, pierced, pinched, and partially broken wires. Also inspect the related connectors for broken, bent, pushed out, spread, corroded, or contaminated terminals. Perform the BODY VERIFICATION TEST - VER 1. Body Verification Test
2. VERIFY OPERATION OF THE VEHICLE CHARGING SYSTEM
NOTE:
- Troubleshoot any PCM charging/cranking DTCs before proceeding.
- Ensure the battery is fully charged.
Q: Are any charging system DTCs present?
YES: Refer to appropriate DTC diagnostic information.
NO: Replace the Instrument Cluster. Perform the BODY VERIFICATION TEST - VER 1. Body Verification Test