All Door Locks Inoperative
*ALL DOOR LOCKS INOPERATIVE
For a complete wiring diagram Consult Diagrams/Electrical.
Diagnostic Test
1. DTC PRESENT
Turn the ignition on.
With the scan tool , read DTC's.
Does the scan tool display any Door Lock or Cluster related DTC's?
Yes
- Repair the DTC's.
No
- Go To 2
2. FUSE No. 9 OPEN
Turn the ignition off.
With the fuse installed, test both sides of fuse No. 9 in the Junction Block.
Is there 12 volts on both sides of the fuse?
Yes
- Go To 3
No
- Replace the fuse if open and retry the system. If the fuse blows, locate and repair a short to the Instrument Cluster. The 12 volt supply to the fuse is a bus bar in the IPM.
- Perform BODY VERIFICATION TEST - VER 1.Body Verification Test
3. (A924) FUSED B+ CIRCUIT OPEN
Disconnect the Cluster C1 connector.
Using a 12-volt test light connected to ground, check both (A924) Fused B+ circuits in the Cluster connector.
Does the test light illuminate brightly at both terminals?
Yes
- Go To 4
No
- Repair the Fused B+ circuits for an open.
- Perform BODY VERIFICATION TEST - VER 1.Body Verification Test
4. (Z946) GROUND CIRCUIT OPEN
Using a 12-volt test light connected to 12-volts, check the (Z946) Ground circuit in the Cluster connector.
Does the test light illuminate brightly?
Yes
- Replace the Instrument Cluster.
- Perform BODY VERIFICATION TEST - VER 1.Body Verification Test
No
- Repair the (Z946) Ground circuit for an open.
- Perform BODY VERIFICATION TEST - VER 1.Body Verification Test