Bus (+/-) Signals Open From BCM
Tests 1 - 4:
Tests 5 - 6:
SYMPTOM
BUS +/- SIGNALS OPEN FROM BODY CONTROL MODULE
POSSIBLE CAUSES
- Open ground circuit at the junction block connector C2
- Open ground circuit at the junction block connector C3
- Open fused B+ circuit (junction block)
- Open ground circuit at the junction block body control module conn CAV 1
- Open ground circuit at the junction block body control module conn CAV 20
- Body control module