A/C Control EBL Switch Failure (MTC)
Tests 1 - 3:
Tests 4 - 8:
SYMPTOM
A/C CONTROL EBL SWITCH FAILURE (MANUAL A/C)
WHEN MONITORED
With the ignition ON.
SET CONDITION
The BCM detects the EBL switch stuck in the depressed position for at least 30 seconds.
POSSIBLE CAUSES
- Control head short to ground
- Mode switch MUX circuit short to ground
- Mode switch MUX circuit short to sensor ground
- Body control module - mode switch MUX short to ground
- Control head - button sticks
- Control head - mode MUX incorrect
- Control head - open switch
- Control head switches okay