Evaporator Temperature Sensor Failure
Tests 1 - 2:
Tests 3 - 7:
Tests 8 - 12:
SYMPTOM
EVAPORATOR TEMPERATURE SENSOR FAILURE
WHEN MONITORED
With the ignition ON.
SET CONDITION
The BCM detects an abnormally high or low voltage on the evaporator temperature sensor signal.
POSSIBLE CAUSES
- Evaporator temperature sensor signal CKT short to voltage
- Evaporator temperature sensor open
- Evaporator temp sensor signal CKT open
- Sensor ground open
- Body control module - evaporator temp sensor stays high
- Evaporator temperature sensor - code returns
- Evaporator temperature sensor - code with A/C operating
- System is operational
- Evaporator temp sensor signal circuit short to ground
- Evaporator temp sensor signal CKT short to sensor ground
- Body control module - Evaporator temp sensor stays low