Operation CHARM: Car repair manuals for everyone.

P0133

Tests 1 - 4:




Tests 5 - 6:





SYMPTOM
P0133-1/1 O2 SENSOR SLOW RESPONSE

WHEN MONITORED
Start engine. Allow engine to idle. For 1st part of test, if limits are exceeded, test passes. If not, 2nd part of test runs. amb/batt temp >44 °F, Baro >22.13" H2O, battery >10.5 volts, MAP >11.79 & <18.15" H2O, RPM >1350 & <2200 and vss >50 and <65.

SET CONDITION
The oxygen sensor signal voltage is switching from below 0.39 volts to above 0.58 volts and back fewer times than required.

POSSIBLE CAUSES
- Intermittent condition
- Exhaust leak
- O2 Sensor signal circuit voltage drop
- O2 Sensor ground circuit voltage drop
- O2 Sensor