P0153
Tests 1 - 4:
Tests 5 - 6:
SYMPTOM
P0153-2/1 O2 SENSOR SLOW RESPONSE
TEST NOTE
All symptoms listed above are diagnosed using the same tests. The title for the tests will be P0133-1/1 O2 SENSOR SLOW RESPONSE.
WHEN MONITORED
With ECT greater than 147 °F, after reaching a vehicle speed of 10 mph, and the throttle remaining open (off idle) for 2 minutes, bring the vehicle to a stop and allow the engine to idle with the transmission in DRIVE.
SET CONDITION
The oxygen sensor signal voltage is switching from below 0.27 volts to above 0.62 volts and back fewer times than required.
POSSIBLE CAUSES
- Intermittent condition
- Exhaust leak
- O2 Sensor signal circuit voltage drop
- O2 Sensor ground circuit voltage drop
- O2 Sensor