6: Condenser Fan Does Not Operate
Inspection Procedure 6: Condenser fan does not operate Radiator Fan and Condenser Fan Drive Circuit.CIRCUIT OPERATION
^ The fan control module is powered from fusible link number 5.
^ The ECM MAT> or PCM judges the required revolution speed of radiator fan motor and condenser fan motor using the input signals transmitted from A/C switch, automatic compressor controller, vehicle speed sensor and engine coolant temperature sensor. The ECM
TECHNICAL DESCRIPTION
The cause could be a malfunction of the condenser fan motor or of the fan control module.
TROUBLESHOOTING HINTS
^ Malfunction of condenser fan motor
^ Malfunction of fan control module
DIAGNOSIS
STEP 1. Check the condenser fan motor.
Q: Is the condenser fan in good condition?
YES: Replace the radiator fan motor and fan control module assembly. Then go to Step 3.
NO: Go to Step 2.
STEP 2. Check the fan control module.
Refer to Fan Control Relay Continuity Check.
Q: Is the fan control module in good condition?
YES: Go to Step 3.
NO: Replace the fan control module, then go to Step 3.
STEP 3. Check the symptoms.
Q: Does the condenser fan operate correctly?
YES: This diagnosis is complete.
NO: Return to Step1.