Operation CHARM: Car repair manuals for everyone.

Convertible Top: 9918






9918 - TRUNK LATCH UNLOCKED SIGNAL CIRCUIT SHORT TO GROUND





- When Monitored: Continuously, with the ignition on.
- Set Condition: When the Power Top Control Module (PTCM) senses that both Trunk Latch Unlocked signal and Trunk Latch Locked signal circuits are grounded.





Always perform the Pre-Diagnostic Troubleshooting procedure before proceeding.

Diagnostic Test

1. Trunk Latch Assembly





Turn the ignition off.

Disconnect the Trunk Latch Assembly C1 harness connector.

NOTE: Check connectors - Clean/repair as necessary.


Turn the ignition on.

With the DRB III(R), select Input/Output Display and monitor the TRUNK LTCH UNLCK SW.

Does the DRBIII(R) display TRUNK LTCH UNLCK SW "UNLOCKED"?

Yes

- Replace the Trunk Latch Assembly.
- Perform POWER TOP VERIFICATION TEST Power Top Verification Test.

No

- Go To 2

2. Trunk Latch Unlocked Signal Circuit for Short to Ground





Turn the ignition off.

Disconnect the Power Top Control Module C1 harness connector.

NOTE: Check connectors - Clean/repair as necessary.


Measure the resistance between ground and the Trunk Latch Unlocked Signal Circuit.

Is the resistance below 100 kohms?

Yes

- Repair the Trunk Latch Unlocked signal circuit for a short to ground.
- Perform POWER TOP VERIFICATION TEST Power Top Verification Test.

No

- Replace the Power Top Control Module.
- Perform POWER TOP VERIFICATION TEST Power Top Verification Test.