1745-01
1745-01 NO COMMUNICATION FROM HVAC SHORTED TO BATTERY
- When Monitored: With the ignition on.
- Set Condition: Serial Communication K2 failure between the A/C Heater Control Module and the Instrument Cluster.
Diagnostic Test
1. MEASURE THE VOLTAGE OF THE SERIAL COMMUNICATION K2 CIRCUIT
Turn the ignition off.
Disconnect the Instrument Cluster harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Turn the ignition on.
Measure the voltage of the Serial Communication K2 circuit.
Is the voltage above 5.0 volts?
No
- Replace the Instrument Cluster.
- Perform BODY VERIFICATION TEST. Body Verification Test
Yes
- Go to 2
2. DISCONNECT THE A/C HEATER CONTROL MODULE
Turn the ignition off.
Disconnect the A/C Heater Control Module harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Turn the ignition on.
Measure the voltage of the Serial Communication K2 circuit.
Is the voltage above 5.0 volts?
Yes
- Repair the Serial Communication K2 circuit for a short to voltage.
- Perform BODY VERIFICATION TEST. Body Verification Test
No
- Replace the A/C Heater Control Module.
- Perform BODY VERIFICATION TEST. Body Verification Test