1817-02
1817-02 REVERSE LAMP CIRCUIT SHORT TO VOLTAGE
When Monitored and Set Condition
- When Monitored: Always monitored with system active at each ignition cycle.
- Set Condition: If the SLA detects a short to voltage on the Reverse Lamp Supply circuit.
1. TEST REVERSE LAMP SUPPLY CIRCUIT SHORT TO VOLTAGE
Turn the ignition off.
Disconnect the Shift Lever Assembly harness connector.
NOTE: Check connector - Clean/repair as necessary.
Measure the voltage of the Reverse Lamp Supply circuit.
Is voltage present?
No
Replace the Shift Lever Assembly.
Yes
- Repair the Reverse Lamp Supply circuit for a short to voltage.
- Perform NAG1 TRANSMISSION VERIFICATION TEST. Transmission Verification Test