1725-00
1725-00 ALARM TRIGGERED BY TOW-AWAY PROTECTION
- When Monitored: Continuous with the ignition on.
- Set Condition: When the Central Locking Pump/Security System Module (CLP/SSM) senses a circuit failure.
Diagnostic Test
1. MONITOR THE CIRCUIT STATUS WITH THE DRB III
Turn the ignition on.
With the DRB III(R), monitor the Tow-Away Alarm Switch state.
Does the DRB III(R) display the Tow-Away Alarm Switch state as OFF?
Yes
- Go To 4
No
- Go To 2
2. DISCONNECT THE TOW-AWAY ALARM SWITCH
Turn the ignition off.
Disconnect the Tow-Away Alarm Switch harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Turn the ignition on.
With the DRB III(R), monitor the Tow-Away Alarm Switch state.
Does the DRB III(R) display the Tow-Away Alarm Switch state as OFF?
Yes
- Replace the Tow-Away Alarm Switch.
- Perform VTSS VERIFICATION TEST. VTSS Verification Test
No
- Go to 3
3. MEASURE THE RESISTANCE OF THE SWITCH SENSE CIRCUIT
Turn the ignition off.
Disconnect the CLP/SSM harness connector.
Measure the resistance of the Tow-Away Alarm Switch Sense circuit at the CLP/SSM C3 harness connector.
Is the resistance below 5 ohms?
Yes
- Repair the Tow-Away Alarm Switch Sense circuit for a short to ground.
- Perform VTSS VERIFICATION TEST. VTSS Verification Test
No
- Replace the Central Locking Pump/Security System Module.
- Perform VTSS VERIFICATION TEST. VTSS Verification Test
4. INTERMITTENT WIRING AND CONNECTORS
The condition that caused this DTC to set is currently not present. Inspect the related wiring harness for a possible intermittent condition.
NOTE: Check connectors - Clean/repair as necessary. Poor pin to terminal connections can set DTCs.
NOTE: Check for any Technical Service Bulletins that may apply.
Using the wiring diagram/schematic as a guide, inspect the wiring and connectors specific to this DTC. Wiggle the wires while checking for shorts and open circuits.
Were there any problems found?
Yes
- Repair as necessary.
- Perform VTSS VERIFICATION TEST. VTSS Verification Test
No
- The condition that caused this DTC to set is currently not present. Inspect the related wiring harness for a possible intermittent condition.