1729-00
1729-00 CENTRAL LOCKING PUMP/SECURITY SYSTEM MODULE INTERNAL FAILURE
- When Monitored: Continuous.
- Set Condition: If the Central Locking Pump/Security System Module (CLP/SSM) detects an internal malfunction, the DTC is set.
Diagnostic Test
1. MEASURE THE VOLTAGE OF THE CLP/SSM POWER CIRCUIT
Turn the ignition off.
Disconnect the CLP/SSM harness connector.
Measure the voltage of the Fused B(+) circuit (cavity 2) at the CLP/SSM C2 harness connector.
Is the voltage between 12 and 16 volts?
Yes
- Go to 2
No
- System voltage must be between 12 and 16 volts. Repair the voltage concern as necessary.
- Perform VTSS VERIFICATION TEST. VTSS Verification Test
2. MEASURE THE VOLTAGE OF THE CLP/SSM POWER CIRCUIT
Measure the voltage of the Fused B(+) circuit (cavity 4) at the CLP/SSM C2 harness connector.
Is the voltage between 12 and 16 volts?
Yes
- Replace the Central Locking Pump/Security System Module.
- Perform VTSS VERIFICATION TEST. VTSS Verification Test
No
- System voltage must be between 12 and 16 volts. Repair the voltage concern as necessary.
- Perform VTSS VERIFICATION TEST. VTSS Verification Test