P0460
P0460 - FUEL LEVEL SENSOR CIRCUIT
When Monitored and Set Condition
- When Monitored: The Powertrain Control Module (PCM) monitors the fuel level at ignition on.
- Set Condition: If the PCM does not see a change in the fuel level over a set amount of miles, the test will fail. Two Trip Fault.
Diagnostic Test
1. FUEL GAUGE OPERATION
Turn the ignition off.
Perform the *FUEL GAUGE INOPERATIVE diagnostic test.
After performing the *FUEL GAUGE INOPERATIVE test, use the DRB III(R) to erase PCM DTCs.
Turn the ignition off, then back on.
With the DRB III(R), read PCM DTCs.
Monitor the DRB III(R) for this DTC.
NOTE: It may be necessary to take the vehicle on a test drive.
It may be necessary to take the vehicle on a test drive.
Did this DTC set again?
Yes
- If the *FUEL GAUGE INOPERATIVE test passed, replace and program the Powertrain Control Module.
- Perform POWERTRAIN VERIFICATION TEST - VER 2. Powertrain Verification Test - Ver 2
No
- Test Complete.