Engine Oil Sensor Performance
P0521 - ENGINE OIL SENSOR PERFORMANCE
When Monitored and Set Condition
- When Monitored: With the engine running.
- Set Condition: Anytime the Powertrain Control Module (PCM) senses the Oil Quality value is above 4.0.
-
NOTE: The engine oil must be changed before this test can be accurately conducted.
Diagnostic Test
1. CHECK FOR CURRENT DTC
Turn the ignition on.
With the DRB III(R), read PCM DTCs.
Is this DTC present?
Yes
- For complete diagnosis of this DTC, refer to (P0521) ENGINE OIL SENSOR QUALITY PERFORMANCE.
No
- Go To 2
2. INTERMITTENT WIRING AND CONNECTORS
The conditions necessary to set this DTC are not present at this time.
NOTE: Check connectors - Clean/repair as necessary. Poor pin to terminal connections can set DTCs.
Using the wiring diagram/schematic as a guide, inspect the wiring and connectors specific to this DTC. Wiggle the wires while checking for shorts and open circuits.
NOTE: Check for any Technical Service Bulletins that may apply.
Were there any problems found?
Yes
- Repair as necessary.
- Perform POWERTRAIN VERIFICATION TEST - VER 2. Powertrain Verification Test - Ver 2
No
- The condition that caused this DTC to set is currently not present. Inspect the related wiring harness for a possible intermittent condition.