Lamp Out Indicator: Testing and Inspection
LAMP OUTAGE INDICATOR CIRCUIT
- When Monitored: With the ignition on.
- Set Condition: Lamp Outage Indicator circuit failure between the Illumination Control Module and the Instrument Cluster.
Diagnostic Test
1. THE LAMP OUTAGE INDICATOR LAMP/INSTRUMENT CLUSTER
Turn the ignition off.
Disconnect the Instrument Cluster C1 harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Turn the ignition on.
Measure the voltage of the Lamp Outage Indicator circuit at the Instrument Cluster C1 harness connector.
Is the voltage above 10 volts?
Yes
- Inspect the Lamp Outage Indicator Lamp. If OK, replace the Instrument Cluster.
- Perform BODY VERIFICATION TEST. Body Verification Test
No
- Go to 2
2. MEASURE LAMP OUTAGE INDICATOR CIRCUIT RESISTANCE
Turn the ignition off.
Disconnect the Illumination Control Module harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Measure the resistance of the Lamp Outage Indicator circuit from the Illumination Control Module D harness connector to the Instrument Cluster C1 harness connector.
Is the resistance below 5.0 ohms?
Yes
- Replace the Illumination Control Module.
- Perform BODY VERIFICATION TEST. Body Verification Test
No
- Repair the Lamp Outage Indicator circuit for an open.
- Perform BODY VERIFICATION TEST. Body Verification Test