Wipers Run Continuously With Ignition On
*WIPERS RUN CONTINUOUSLY WITH IGNITION ON
Diagnostic Test
1. MEASURE WIPER SWITCH MUX CIRCUIT VOLTAGE
NOTE: If any BCM DTCs are set, diagnose them first before continuing.
Disconnect the BCM harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Turn the ignition on.
Measure the voltage of the Wiper Switch MUX circuit at cavity 65 of the BCM harness connector.
Is voltage present?
Yes
- Go to 2
No
- Replace the Body Control Module.
- Perform BODY VERIFICATION TEST. Body Verification Test
2. MEASURE MULTI-FUNCTION SWITCH VOLTAGE
Turn the ignition off.
Disconnect the Multi-Function Switch harness connector.
NOTE: Check connectors - Clean/repair as necessary.
Turn the ignition on.
Measure the voltage of the Wiper Switch MUX circuit at cavity 7 of the Multi-Function Switch harness connector.
Is voltage present?
Yes
- Repair the Wiper Switch MUX circuit for a short to voltage.
- Perform BODY VERIFICATION TEST. Body Verification Test
No
- Replace the Multi-Function Switch.
- Perform BODY VERIFICATION TEST. Body Verification Test