Operation CHARM: Car repair manuals for everyone.

With 3T6XXX or 4T6XXX Series Distributors

Part No. T3T61971 T3T61972 T3T61973 T3T626778 T3T63175 T4T63371 T4T63372
Centrifugal Advance Starts 0 at 600 Degrees At RPM (deg @ rpm)0 at 600 Degrees At RPM (deg @ rpm)0 at 600 Degrees At RPM (deg @ rpm)0 at 750 Degrees At RPM (deg @ rpm)0 at 500 Degrees At RPM (deg @ rpm)0 at 600 Degrees At RPM (deg @ rpm)0 at 600 Degrees At RPM (deg @ rpm)
Intermediate Cent. Advance 7 at 1900 Degrees At RPM (deg @ rpm)7 at 1900 Degrees At RPM (deg @ rpm)7 at 1900 Degrees At RPM (deg @ rpm)4.5 at 1250 Degrees At RPM (deg @ rpm)6 at 1250 Degrees At RPM (deg @ rpm)6.5 at 1150 Degrees At RPM (deg @ rpm)5 at 1000 Degrees At RPM (deg @ rpm)
Full Cent. Advance 8.5 at 2500 Degrees At RPM (deg @ rpm)8.5 at 2500 Degrees At RPM (deg @ rpm)8.5 at 2500 Degrees At RPM (deg @ rpm)13 at 3000 Degrees At RPM (deg @ rpm)13 at 2650 Degrees At RPM (deg @ rpm)12.5 at 2500 Degrees At RPM (deg @ rpm)16.5 at 3000 Degrees At RPM (deg @ rpm)
Vacuum to Start Plunger 5.12 Inch Of Mercury (in Hg)5.12 Inch Of Mercury (in Hg)3.15 Inch Of Mercury (in Hg)3.15 Inch Of Mercury (in Hg)3.15 Inch Of Mercury (in Hg)3.1 Inch Of Mercury (in Hg)3.1 Inch Of Mercury (in Hg)
Max. Vacuum Advance 30 at 11.8 Degrees At Inches Mercury (deg @ in hg)23 at 11 Degrees At Inches Mercury (deg @ in hg)20 at 14 Degrees At Inches Mercury (deg @ in hg)23 at 11 Degrees At Inches Mercury (deg @ in hg)23 at 10.25 Degrees At Inches Mercury (deg @ in hg)23 at 11 Degrees At Inches Mercury (deg @ in hg)23 at 11 Degrees At Inches Mercury (deg @ in hg)
Maximum Retard --- --- --- --- 18 at 18 Degrees At Inches Mercury (deg @ in hg)
Note: Distributor Pressure.
7 at 17.7 Degrees At Inches Mercury (deg @ in hg)
Note: Distributor Pressure.
7 at 17.7 Degrees At Inches Mercury (deg @ in hg)
Note: Distributor Pressure.