Oil Charge Additions
If there are no signs of external oil leakage, proceed as follows to add oil to system during component replacement.1. Discharge system refer to, Heating and Air Conditioning/Service and Repair and measure amount of oil collected in discharge container. The amount of oil collected when discharging system must be replaced with new refrigeration oil to maintain proper oil charge.
2. Remove defective components. Measure amount of oil remaining in compressor, if removed.
3. Add correct amount of oil to components. Refer to Air Conditioning/Specifications/Capacities.
4. Install replacement components, then evacuate and recharge system.