Operation CHARM: Car repair manuals for everyone.

Wiper Switch: Testing and Inspection

Fig. 11 Two Speed Wiper Switch Continuity Chart:





Fig. 12 Intermittent Wiper Switch Continuity Chart:





1. Disconnect electrical connector to switch at body wiring harness connector.
2. Operate switch in all positions, and check continuity between terminals with an ohmmeter. The first (clockwise) position is the Off position. Next is the slide for the Delay wipe, with counterclockwise rotation, reducing the delay. Low is the next detent position. High is the full counterclockwise detent position. In any wiper mode, if the knob is pushed in all the way, the washer circuit will be completed.
3. If continuity is not as specified in charts, replace switch.