Part No. | T3T65476 | T3T65571 | T3T65572 | T4T63373G |
Centrifugal Advance Starts | 0 at 800 Degrees At RPM (deg @ rpm) | 0 at 800 Degrees At RPM (deg @ rpm) | 0 at 800 Degrees At RPM (deg @ rpm) | 0 at 600 Degrees At RPM (deg @ rpm) |
Intermediate Cent. Advance | 4.5 at 1400 Degrees At RPM (deg @ rpm) | 4.5 at 1400 Degrees At RPM (deg @ rpm) | 4.5 at 1400 Degrees At RPM (deg @ rpm) | 5 at 1000 Degrees At RPM (deg @ rpm) |
Full Cent. Advance | 9.5 at 3000 Degrees At RPM (deg @ rpm) | 9.5 at 3000 Degrees At RPM (deg @ rpm) | 9.5 at 3000 Degrees At RPM (deg @ rpm) | 17.5 at 3000 Degrees At RPM (deg @ rpm) |
Vacuum to Start Plunger | 2.35 Inch Of Mercury (in Hg) | 3.15 Inch Of Mercury (in Hg) | 2.35 Inch Of Mercury (in Hg) | 3.15 Inch Of Mercury (in Hg) |
Max. Vacuum Advance | 2.5 at 3.15 Degrees At Inches Mercury (deg @ in hg) | 10 at 14.17 Degrees At Inches Mercury (deg @ in hg) | 2.5 at 3.15 Degrees At Inches Mercury (deg @ in hg) | 23 at 11.02 Degrees At Inches Mercury (deg @ in hg) |
Max. Retard | --- | --- | --- | --- |