Operation CHARM: Car repair manuals for everyone.

75 Amp

Bosch 75 HS, 75 Amps, Test Output & Field Current Draw
<cam057-014>
Test Output 30 at 1250
Field Current Draw
Rotate alternator by hand while measuring field currentdraw. Minimum current is measured at 15.0 volts,except 72, 100, or 117 ampere alternator which is 13.0 volts.
2.5-5.0
Note: When hand rotated.