Refrigerant Pressure Sensor / Switch: Service and Repair
FIN-SENSED CYCLING CLUTCH SWITCH - REMOVAL/INSTALLATION1. Remove heater-A/C blower housing.
Wire Harness Grommet:
2. Disconnect the 3 pin wire connector from the sensor. Push the wire grommet through the hole in unit housing and feed connector through.
Fin-sensed Cycling Clutch Switch:
3. Through the air inlet opening to the left of the blower wheel pull the switch from the evaporator.
4. To install, reverse the preceding operation.