Driver Squib Term Shorted to Ground
NOTE: This code becomes active and stored as soon as the malfunction is detected.WHEN MONITORED: Continuously with the ignition ON.
SET CONDITION: With voltage and current on, the driver air bag line 1 or line 2 circuit(s) is other than expected.
POSSIBLE CAUSES:
- Driver air bag line 1 short to ground potential
- Driver air bag line 2 short to ground potential
- Faulty clockspring
- Faulty air bag control module
For diagnostic procedures see DIAGNOSTIC CHARTS/TEST 1A. 1A Testing System Function