Loss of Ignition Run/Start
NOTE: This code becomes active and stored as soon as the malfunction is detected.WHEN MONITORED: Continuously with the ignition ON.
SET CONDITION: With voltage and current on, the ignition run/start circuit is other than expected.
POSSIBLE CAUSES:
- Open ignition run/start circuit
- Open fuse
- Ignition run/start circuit short to ground
- Loose or poor connection at connector terminals
For diagnostic procedures see DIAGNOSTIC CHARTS/TEST 1A. 1A Testing System Function