Data Link Connector: Testing and Inspection
The grounding point for circuit Z12 is the rear of the right cylinder head.Circuit Z12 also supplies a ground for the PCM high current drivers.
If the system loses ground for the Z12 circuits at the rear of the right cylinder head, the vehicle will not operate. Check the connection at the ganged ground circuit eyelet.