Manifold Pressure/Vacuum Sensor
Vacuum in Inches of Mercury MAP sensor Signal Voltage
.39 in Hg 4.90 V
3.34 in Hg 4.60 V
6.30 in Hg 3.60 V
9.25 in Hg 3.10 V
12.20 in Hg 2.60 V
15.15 in Hg 2.10 V
18.11 in Hg 1.60 V
21.06 in Hg 1.10 V
24.01 in Hg 0.60 V
26.97 in Hg 0.31 V
Condition Expected Output Voltage
High Vacuum (Idle/Deceleration) 0.5 to 1.5 volts
Medium Vacuum (Cruise/Slight Acceleration) 1.5 to 3.0 volts
Low Vacuum (Hard Acceleration/Mechanical Failure) 3.0 to 4.5 volts
NOTE: Any reading of 0 volts or over 5 volts indicates a problem in the MAP sensor circuit.