Starter Motor
Power rating 1.2 kilowattsVoltage 12 Volts
Free Running Test:
- Voltage 11 Volts
- Amperage Draw 73 Amp
- Minimum Speed 3,401 rpm
Solenoid closing Voltage 7.5 Volts
Cranking Amperage Draw Test 150 to 200 Amps
NOTE: Engine should be up to operating temperature. Extremely heavy oil or tight engine will increase starter amperage draw.