Operation CHARM: Car repair manuals for everyone.

Driver Squib Circuit Open (Stored)

SYMPTOM
DRIVER SQUIB CIRCUIT OPEN (STORED)

WHEN MONITORED
Continuously with ignition ON

SET CONDITION
The ACM has detected an open or high resistance in the Driver Squib Circuits.

POSSIBLE CAUSES
- Driver airbag connector disconnected
- Driver airbag line 1 shorted to driver airbag line 2
- Clockspring shorted
- Driver airbag module shorted
- ACM defective, driver airbag circuit shorted